Firing ceramics that contain organic binders poses a unique safety consideration. When heated, organic binders release combustible vapors. Under some conditions, concentrations may reach flammable or explosive levels during binder burn-out.

Monitoring combustible gas concentrations can provide a layer of safety. In addition, knowing how the combustible gas concentration varies over time, and the peak it reaches, is useful process data. It can increase understanding of how the firing proceeds over time, and it can inform decisions about the safe and efficient loading of the kiln. It can therefore be desirable to monitor combustible gas concentrations rather than, or in addition to, oxygen. Before measurements can be made, however, some important hurdles must be cleared.

Detection Approaches

The first step toward monitoring flammability is typically to identify the flash point and lower flammable limit of all combustible substances in use. Generally speaking, the flash point is the temperature above which a substance has enough vapor pressure to produce a flammable mixture near its surface. The lower flammable limit is the concentration in air above which it is possible to propagate a combustion wave (an explosion).

Next, an analyzer is selected that has a detector suitable for the particular combustible vapors. Hopefully, the analyzer can measure all combustibles that might be present more or less equally, and can be heated above the flash point of the substances it is trying to detect.

The problem with this standard approach is that good flammability data for the organic binders are hard to come by. They do not simply vaporize as the firing proceeds; the binder often has such low volatility that it will not readily vaporize. Instead, as the temperature climbs, temperature- and oxygen-dependent mechanisms generate a variety of combustible vapors.

At first, vaporization will occur, especially for whatever fraction of the binder has low molecular weight. For the heavier parts, however, the vapor pressure is insufficient to release significant quantities. A second mechanism, volatilization, becomes important as heavier organics partially break down and are released as gases. At even higher temperatures, the remaining binder may undergo surface combustion, which can generate an even wider variety of partially oxidized flammable gases, even carbon monoxide. The types of combustible gases in the kiln atmosphere become too complex to predict.

The temperatures at which the majority of combustible gases evolve in the kiln fall in the range from 200-250°C. This is the temperature range at which the flash point begins to approach the auto ignition temperature—in other words, when the combustible tends to burn rather than vaporize.

Analyzer Features

Some important features of an analyzer are therefore clear. Ideally, an analyzer should have a broad response to all combustibles, a uniform sensitivity to each and every one, and the ability to operate at 250°C or more. A detector that responds only to a specific combustible gas, or that varies too much for different gases, cannot be properly calibrated and so cannot be made accurate. Sample conditioning cannot be performed if it involves a decrease in temperature, since filtering out the resulting condensate will also remove the combustibles from the sample stream and produce false low readings.

Selection of an analyzer for monitoring kilns leads either to a flame ionization or flame temperature detector. Non-dispersive infrared sensors are limited in operating temperature and cannot be accurately applied to the broad range of combustibles found in kilns. The two detector types most likely to produce a satisfactory response both use a sensing flame. Of these two, the flame temperature type is preferred for its ability to also detect non-hydrocarbon substances (e.g., carbon monoxide and hydrogen), which are not detected by flame ionization.

Important Considerations

Several factors should be considered when monitoring combustible gases in a kiln:

•  Heating all sample-wetted parts of the analyzer and sampling system to 250°C will prevent condensation. The sample stays intact. The measurement includes all combustible vapors.

•  Sample pumps cannot provide the same level of reliability as an aspirated sampling system and should be avoided.

•  A flame-based detector has the best chance to measure the wide range of combustible vapors that might be present. A flame temperature type will include the widest possible range of combustible gases and vapors, including non-hydrocarbons such as hydrogen and carbon monoxide.

•  Flammability data for organic binders may be difficult to obtain. A rough estimate for the lower flammable limit in air is 50% of stoichiometric. Another useful rough estimate is one pound of binder per 340 standard cubic feet of air (50 g/m3).

•  Near the flash point, the vapor pressure tends to double for every 10°C rise in temperature. Small changes in temperature can have a large effect. Cooling the sample a bit can condense out half the combustibles.

 For additional information, contact the author at (973) 575-9114 or cschaeffer@controlinstruments.com, or visit www.controlinstruments.com.


 

To find suppliers of combustible gas analyzers and other products, visit www.ceramicindustry.com/suppliers.

Did you enjoy this article? Click here to subscribe to Ceramic Industry Magazine.

Recent Articles by Chris Schaeffer

You must login or register in order to post a comment.

Multimedia

Videos

Image Galleries

June 2014 Issue Highlights

Our June 2014 issue is now available!

Podcasts

Manufacturing Day 2014

Manufacturing Day organizers share their insights with Managing Editor Kelsey Seidler.

More Podcasts

Ceramic Industry Magazine

CI September 2014 cover

2014 September

You won't want to miss the CI Top 10, traditionally our most popular article of the year!

Table Of Contents Subscribe

THE CERAMIC INDUSTRY STORE

M:\General Shared\__AEC Store Katie Z\AEC Store\Images\Ceramics Industry\handbook of advanced ceramics.gif
Handbook of Advanced Ceramics Machining

Ceramics, with their unique properties and diverse applications, hold the potential to revolutionize many industries, including automotive and semiconductors.

More Products

Clear Seas Research

Clear Seas ResearchWith access to over one million professionals and more than 60 industry-specific publications,Clear Seas Research offers relevant insights from those who know your industry best. Let us customize a market research solution that exceeds your marketing goals.

Directories

CI Data Book July 2012

Ceramic Industry's Directories including Components, Equipment Digest, Services, Data Book & Buyers Guide, Materials Handbook and much more!

STAY CONNECTED

facebook_40px twitter_40px  youtube_40pxlinkedin_40google+ icon 40px